RADIO AUTO RELAXATION BOUNDS

(Noise Reduction, Radio Noise)

HGDefinitionMob&Port.jpg

This vector sets the limits on relaxation with frequency for the auto mode of noise suppression.

HGSelections.jpg

You must set the RADIO AUTO RELAXATION BOUNDS and field according to the following rules :

1. RADIO AUTO RELAXATION BOUNDS length must be equal to 4

2. [X] of RADIO AUTO RELAXATION BOUNDS is from "0" to "10", and

3. [Y] of RADIO AUTO RELAXATION BOUNDS is from "0" to "10",and

4. [X] is NOT greater than [Y]

 

IconSmallNote.png

RADIO AUTO RELAXATION BOUNDS is the vector of two 8-bit integers:

Each 2 hex numbers represents a 8 bit signed integer. The range for the each of the two numbers ([X] and [Y]) is 0 to 10 inclusive.

HGAccessedOnly.jpg

 When the radio is model / option capable.

 

GoArrow.jpg

Go to the Radio Noise Reduction Window